RTD Cu

Copper : Cu10, Cu20, Cu25, Cu50, Cu100, Cu200, Cu500, Cu1000, Cu2000

TEST - FREE APP

Google Play

Standards Cu

How to use the Applications

Hidden Menu

  • Language
  • Unit
  • Precision
  • Calculator
  • Table
  • Chart
  • Range

Standard

  • 0.00427
  • GOST 6651-94 – 0.00428
  • GOST 6651-94 – 0.00426
  • GOST 6651-2009 / OIML R84 – 0.00428
  • OIML R84 – 0.00426

Class

  • ————————-
  • F 0.03 | W0.03 | 1/10DIN | 1/10B
  • F 0.06 | W0.06 | 1/5DIN | 1/5B
  • F 0.1 | W 0.1 | 1/3DIN | 1/3B
  • AA
  • A | F 0.15 | W 0.15 | 1/2DIN | 1/2B
  • B | F 0.3 | W 0.3 | 1DIN | 1B
  • C | F 0.6 | W 0.6 | 2DIN | 2B

Language

en English; ca Catalan; bn Bengali; bg Bulgarian; sw Swahili; zh Chinese; cs Czech; de German; da Danish; et Estonian; es Spanish; am Amharic; eu Basque; fi Finnish; fr French; el Greek; gu Gujarati; hu Hungarian; id Indonesian; iw Hebrew; hi Hindi; is Icelandic; it Italian; ja Japanese; kn Kannada; ko Korean; ta Tamil; lt Lithuanian; lv Latvian; ml Malayalam; mr Marathi; ms Malay; nl Dutch; no Norwegian; tl Tagalog (Filipino); ur Urdu; pl Polish; pt Portuguese (Portugal, Brazil); ro Romanian; ru Russian; ar Arabic; sv Swedish; sl Slovenian; sk Slovak; sr Serbian; te Telugu; th Thai; tr Turkish; uk Ukrainian; vi Vietnamese; cy Welsh; af Afrikaans; sq Albanian; az Azerbaijani; be Belarusian; my Myanmar (Burmese); bs Bosnian; ceb Cebuano; hr Croatian; eo Esperanto; fy Frisian; gl Galician; ka Georgian; ht Haitian Creole; ha Hausa; haw Hawaiian; yo Yoruba; hmn Hmong; ga Irish; yi Yiddish; kk Kazakh; km Khmer; ky Kyrgyz; co Corsican; lo Lao; lb Luxembourgish; la Latin; mk Macedonian; mg Malagasy; mt Maltese; mi Maori; mn Mongolian; ne Nepali; ny Nyanja (Chichewa); hy Armenian; ps Pashto; pa Punjabi; fa Persian; sm Samoan; st Sesotho; sn Shona; sd Sindhi; so Somali; si Sinhala (Sinhalese); gd Scots Gaelic; tg Tajik; jv Javanese; uz Uzbek; xh Xhosa; ku Kurdish; zu Zulu; ig Igbo

Unit

  • [ºC]
  • [ºF]
  • [K]
  • [ºR]

Precision

  • 1
  • 0.1
  • 0.01
  • 0.001
  • 0.0001

Calculator

The values ​​in the field above and below the Temperature field are the sensor errors for the selected Class.

Temperature too low

If the temperature is below the minimum, it is displayed in blue.

Temperature too high

If the temperature is above the maximum, it is displayed in red.

Resistance too low

If the resistance is below the minimum, it is displayed in blue.

Resistance too high

if the resistance is above the maximum, it is displayed in red.

Table

Chart

The chart can be enlarged with 2 fingers. By clicking on a point on the chart, its coordinates will be displayed.

Range

The Range depends on the Standard

Close

Select YES if you want to close the application, NO if you want to stay in the application

Test our app

We encourage you to test free applications before purchasing.